Files
RuView/docs
ruv 3cd360f9e2 fix(ruview): CSI loss survives stray and reordered sequence numbers
Live RTL8721Dx capture (node 3, COM10) reported 97% loss: one stray
sequence value (+52,835, then straight back) was counted as 52,834 lost
frames, and every late UDP packet re-counted its gap. The tracker now
treats a single out-of-window value as a stray, needs two agreeing frames
to accept a counter reset, and lets a late packet fill its own gap
(seqReordered / seqStrays / seqResyncs in the summary). Against ground
truth on the live board (unique sequence numbers over the span): 4,783 of
4,783 present, loss 0, 9 strays; the tracker matched both.

ADR-373 Amendment 2 records the live Realtek run: devices -> realtek,
7,404/7,404 packets decoded, monitor at 1500000 baud without a reset, and
12,549 live frames analyzed by the WASM kernel.

Co-Authored-By: claude-flow <ruv@ruv.net>
2026-10-01 15:20:21 -04:00
..