mirror of
https://github.com/ruvnet/RuView.git
synced 2026-10-18 21:00:22 -05:00
refactor(firmware): separate acting on temperature from measuring it
Reading the sensor is inert. Reducing transmit power moves every RSSI the node has, at both ends of every link -- introducing that during a three-to-nine node bring-up would give any surprise two candidate causes and no way to separate them. So CONFIG_THERMAL_THROTTLE is now its own option, default off, while monitoring stays on. The first flash therefore reports die temperature and peak without ever changing behaviour, which is exactly what is needed to answer whether these boards run hot in enclosures at all. If none of them ever does -- the likely outcome at ~0.4 W average in a vented box -- throttling never needs enabling and the thresholds cost nothing. Co-Authored-By: claude-flow <ruv@ruv.net> (cherry picked from commit 187eb17ba9549a96aa63ce0fda37888c8c65650c)
This commit is contained in:
1 parent
5419bff2a8
commit
ed006abd58
2 files changed
+21
No files matched your search
@@ -534,6 +534,19 @@ config THERMAL_MONITOR
|
||||
transition (~55-60 C) and sags slowly under its own weight, which never
|
||||
announces itself.
|
||||
|
||||
config THERMAL_THROTTLE
|
||||
bool "Act on the temperature by reducing transmit power"
|
||||
depends on THERMAL_MONITOR
|
||||
default n
|
||||
help
|
||||
Separate from monitoring on purpose. Reading the sensor is inert;
|
||||
reducing transmit power moves every RSSI the node has, and doing that
|
||||
mid-experiment gives any surprise two candidate causes.
|
||||
|
||||
Leave off until the fleet is stable and the logs show a node genuinely
|
||||
running hot. If none ever does -- which is the likely outcome -- this
|
||||
never needs enabling, and the thresholds below cost nothing.
|
||||
|
||||
config THERMAL_WARN_C
|
||||
int "Warn above this die temperature (C)"
|
||||
depends on THERMAL_MONITOR
|
||||
|
||||
@@ -133,12 +133,20 @@ void thermal_tick(void)
|
||||
s_state = next;
|
||||
}
|
||||
|
||||
#ifdef CONFIG_THERMAL_THROTTLE
|
||||
/* Acting on the reading is separate from taking it. Measuring is inert;
|
||||
* changing transmit power mid-experiment moves every RSSI this node has,
|
||||
* which is not something to introduce during a fleet bring-up when any
|
||||
* surprise needs a single candidate cause. Turn this on once the fleet is
|
||||
* stable AND the logs show a node actually gets hot -- if none ever does,
|
||||
* it never needs turning on at all. */
|
||||
switch (s_state) {
|
||||
case THERMAL_CRITICAL: apply_tx_power(TXP_MIN); break;
|
||||
case THERMAL_THROTTLED: apply_tx_power(TXP_STEP2); break;
|
||||
case THERMAL_WARN: apply_tx_power(TXP_STEP1); break;
|
||||
case THERMAL_OK: apply_tx_power(TXP_FULL); break;
|
||||
}
|
||||
#endif
|
||||
|
||||
static int64_t s_last_log_us;
|
||||
int64_t now = esp_timer_get_time();
|
||||
|
||||
Reference in new issue