mirror of
https://github.com/ruvnet/RuView.git
synced 2026-10-22 06:32:35 -05:00
Integrate reviewed source PRs #2201-#2223, #2225-#2231, #2235-#2240, #2242 and #2243 (firmware README hunks remain in #2247). Regenerate one package manifest after integration, validate native Windows test execution, bound MTK listener startup, support official C6 release bundles, and retain stronger release metadata gates.
28 lines
1.2 KiB
Markdown
28 lines
1.2 KiB
Markdown
# ADR-395: Preserve missing numeric CLI values for schema rejection
|
|
|
|
- Status: proposed
|
|
- Date: 2026-10-11
|
|
- Related: ADR-369 (operator CLI)
|
|
|
|
## Context
|
|
|
|
The common device/training CLI flag adapter coerces values with `Number`. A bare
|
|
`--node-id` is parsed as boolean true and becomes node 1; `--node-id=` becomes
|
|
node 0. Both silently select a real node rather than reporting the missing
|
|
numeric argument. The same adapter handles capture deadlines and sample limits.
|
|
|
|
## Decision
|
|
|
|
Retain boolean and empty-string values in the common schema argument adapter so
|
|
existing numeric schemas reject them. Convert explicit non-empty numeric values
|
|
as before, including zero. Keep presentation flags and tool schemas unchanged.
|
|
This change is limited to verbs using the common snake-case argument adapter.
|
|
|
|
## Verification
|
|
|
|
Execute the actual CLI process with both missing-value forms and explicit zero.
|
|
An intentionally invalid UDP port ensures argument validation completes before
|
|
opening a socket. Baseline errors omit node_id for both missing forms; the fixed
|
|
CLI reports those numeric type errors while preserving the explicit zero control.
|
|
This is offline CLI/schema verification, not a radio capture.
|