With restore_axis naming X or Y, a real tool change can now raise the old tool before it crosses the part to its dock, retract the new tool while it is still seated in its dock, travel back raised, descend, and give back part of the retract at the target. The options are restore_z_hop, restore_retract and restore_unretract with their feeds; all are zero as shipped. From Niels Sedat's #29 without the prime-tower registration, the model-skip rule, the shared-stepper sync or the stats hooks. Co-authored-by: Niels Sedat <nlssdt@gmail.com> Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
30 KiB
The toolchanger mod
FlashForge Creator 5 Pro — native toolchanger for Klipper/Mainsail.
Makes the Creator 5 Pro's 4-tool toolchanger and print lifecycle work for
prints started from Mainsail/Moonraker (e.g. sliced in OrcaSlicer), without
the stock touchscreen app in the loop. Based on reverse-engineering the
stock firmwareExe binary (addresses referenced in the source comments),
with some behaviour improved along the way — deliberate divergences are
documented in the file headers.
This is the design side. The checks to run before a first print are in Your first print. What is on this page is what the extras do and why, for someone changing them.
What's in here
| File | Goes to (on the printer) | What it does |
|---|---|---|
pkgs/klipper/payload/klipper/klippy/extras/ff_toolchange.py |
/usr/data/anvil/klipper/klippy/extras/ |
The toolchanger: T0..T3, dock/grab state machine with sensor polling and retries, per-tool G-code offsets (the absolute ~3.2 mm bed-frame Z is applied at every grab), TOOLCHANGE_SET_PRINT_OFFSET (the print-start thermal/bed/layer Z terms), TOOL_Z_ADJUST (per-tool babystep, live, saved on request), TOOLCHANGE_STATUS, TOOLCHANGE_PARK |
pkgs/helixscreen/payload/helixscreen/config/printer_database.d/flashforge_creator5.json |
HelixScreen config/printer_database.d/ |
Printer-database entry so HelixScreen auto-detects both Creator 5 models as tool changers (the Pro and the non-Pro differ only by the chamber heater) |
pkgs/klipper/payload/klipper/klippy/extras/ff_print.py |
/usr/data/anvil/klipper/klippy/extras/ |
[ff_print] — takes over SDCARD_PRINT_FILE and M23, reads bed/nozzle/initial tool/first-layer height out of the file itself, and calls FF_BEFORE_PRINT_START before the file's first line and FF_AFTER_PRINT_END once the job leaves the printing state. Declared in ff-print-macros.cfg; holds no policy of its own |
pkgs/klipper/payload/klipper/klippy/extras/ff_tool.py |
/usr/data/anvil/klipper/klippy/extras/ |
[ff_tool n] — one section per tool; dock_x/dock_y, nozzle_x/y/z and z_adjust are all autosaved (import or calibration + SAVE_CONFIG) |
pkgs/klipper/payload/klipper/klippy/extras/ff_tool_offset.py |
/usr/data/anvil/klipper/klippy/extras/ |
TOOL_CALIBRATE_TOOL_OFFSET / TOOL_LOCATE_SENSOR / TOOL_OFFSET_STATUS — the touchscreen's nozzle XY/Z offset calibration, recovered from the binary and reimplemented in Klipper |
pkgs/klipper/payload/klipper/klippy/extras/ff_legacy.py |
/usr/data/anvil/klipper/klippy/extras/ |
FF_IMPORT_FIRMWARE_CONFIG — one-shot import of the factory/touchscreen JSON into Klipper config. The command and nothing else: no startup behaviour. bin/ff-startup.py is what runs it on the first boot |
pkgs/klipper-config/payload/config/ff-toolchange.cfg |
/usr/data/anvil-data/config/ |
empty [ff_tool 0..3] sections (the per-unit dock/nozzle data is autosaved, nothing unit-specific ships), [ff_toolchange] feeds/geometry, the G28 dock-first wrapper |
pkgs/klipper-config/payload/config/ff-tool-offset.cfg |
/usr/data/anvil-data/config/ |
[ff_tool_offset] — probe geometry and guards for the calibration commands |
pkgs/klipper-config/payload/config/ff-legacy.cfg |
/usr/data/anvil-data/config/ |
[ff_legacy] — stays included permanently; declares the section and, optionally, firmware_config_dir |
pkgs/anvil-core/payload/bin/ffscreen.py |
/usr/data/anvil/bin/ |
Startup status and a progress bar drawn straight onto /dev/fb0. The framebuffer is portrait 480×800@32 and the panel is that buffer turned 90° clockwise (landscape 800×480) — established from FlashForge's own /usr/prog/start.img, 1536000 bytes, which only decodes into a picture read that way. Drawing is done in landscape coordinates and each rectangle is rotated on the way into the buffer, so it costs arithmetic per rectangle and nothing per pixel. Every boot waits for the boards, Klipper, and Moonraker before HelixScreen starts; the first boot also imports calibration. Without this screen the panel stays black through those waits, which reads as a brick and invites a power cut mid-SAVE_CONFIG. make boot-screen renders every frame to PNG on the host; make boot-screen-sim renders the same frames inside the replica using the shipped Python on MIPS; qa/replica/test_boot_screen.py is the gate. |
pkgs/anvil-core/payload/bin/ff-startup.py |
/usr/data/anvil/bin/ |
Everything before HelixScreen. Every boot it hands the toolhead boards over from their bootloaders (calling ff_mcu_bringup.py directly — it owns when klippy opens the ports, so it owns doing this first), starts klipper, and waits for klipper + moonraker to be ready, naming the board or service holding things up and re-handing the boards over on each retry. It runs as two s6-rc oneshots (mcu-bringup, then ff-startup), and the UI depends on the second — starting the UI before that is what produces a screen reporting a disconnected printer with no clue which board is missing. First boot only, once that has happened, it sends FF_IMPORT_FIRMWARE_CONFIG and SAVE_CONFIG over the moonraker API and stamps /usr/data/anvil/.firmware-config-imported. Only a verified save stamps, so a slow boot retries. It always runs and always waits — the MOD_STARTUP and MOD_IMPORT switches went with anvil.conf |
pkgs/klipper-config/payload/config/ff-print-macros.cfg |
/usr/data/anvil-data/config/ |
START_PRINT / END_PRINT / PAUSE / RESUME / CANCEL_PRINT, reconstructed from the app's sequences, plus the _FF_PREFLIGHT calibration and tool-presence gate; declares [ff_print] and the FF_BEFORE_PRINT_START / FF_AFTER_PRINT_END entry points it calls |
pkgs/klipper-config/payload/config/ff-filament.cfg |
/usr/data/anvil-data/config/ |
LOAD_FILAMENT / UNLOAD_FILAMENT / PURGE — the touchscreen's filament-load sequence (grab tool, purge chute, feed) recovered from the binary; unload is a designed retract (the stock app has none) |
pkgs/klipper-config/payload/config/ff-runout.cfg |
/usr/data/anvil-data/config/ |
Runout / clog handling: gives the stock fd_ex* / fm_ex* sensors a runout_gcode that pauses a Mainsail print when the mounted tool runs out or clogs (the app's E0162 / E0163, reported here in plain words); ff_toolchange arms only the mounted tool's sensors |
pkgs/klipper-config/payload/config/printer.base.cfg |
$MODDIR/config/ -> symlinked to /usr/data/anvil-data/config/printer.base.cfg |
FlashForge's printer.base.cfg with the chamber block replaced by [include printer.chamber.cfg]. Klipper can override an option but cannot un-declare a section, and the plain Creator 5 has no chamber heating element, so its heater must be absent rather than neutralised. bin/unpack.sh compares this against each stock package it unpacks and warns if FlashForge's has changed |
Creator5.cfg · Creator5Pro.cfg |
$MODDIR/config/chamber/<Machine>.cfg -> symlinked to /usr/data/anvil-data/config/printer.chamber.cfg |
The one per-model difference: the Pro gets [heater_generic chamber_heater] + [verify_heater] verbatim from FlashForge, the Creator 5 gets only [temperature_sensor chamber] on the same pin. Both ship in anvil-klipper-config and anvil-link-prog.sh links whichever the printer asks for, reading MACHINE= out of FlashForge's own app_startup.sh. They used to be a package per model, which Conflicted — each owned config/printer.chamber.cfg, so the package manager refused the pair and the build had to choose. Nothing is edited at build time, and the payload is no longer model-specific |
pkgs/klipper-config/payload/config/ff-chamber.cfg |
/usr/data/anvil-data/config/ |
M141 / M191 for the chamber heater (Klipper has neither, and the stock app drove the chamber only from its own UI), plus the gate: the macros ask Klipper whether heater_generic chamber_heater exists, so a non-zero chamber target is refused on a machine that does not declare one. Nothing to keep in sync; identical in every package |
docs/notes/ |
(reference only) | Condensed reverse-engineering notes: what the stock app actually does, with binary addresses |
⚠️ Before you start
- The eddy probe's Z home is ~3.2 mm below the real bed plane. The stock
app compensates with an absolute
SET_GCODE_OFFSET Z=+3.2xxat print start. Here everyT<n>grab applies that tool's gap (nozzle_z − station_z + z_adjust) as the Z offset, so Z=0 is the bed whenever a tool is mounted;START_PRINT'sTOOLCHANGE_SET_PRINT_OFFSETonly adds the thermal/bed/thin-layer terms — small, but not negligible:NOZZLE=220 BED=80(the example below) gives 0.045 mm, and a bed at 100 °C or above adds a further 0.08 mm. With no tool mounted, or on an uncalibrated machine, Z=0 is still ~3.2 mm below the plate — the print gate refuses to start in that state. - Where the numbers live. Nothing is read from firmwareExe's JSON at
runtime any more. Feeds and staging positions (
[ff_toolchange]) are plain config inff-toolchange.cfg. Per-unit values —dock_x/dock_y,nozzle_x/y/zandz_adjustper tool,station_x/y/z,cylinder_x/y— are written by the import/calibration commands (configfile.set) and persisted withSAVE_CONFIGinto the#*#block at the end ofprinter.cfg, exactly like PID or input-shaper results. Never put those autosaved options into an included.cfg: this Klipper fork'sSAVE_CONFIGrefuses with "conflicts with included value" and the calibration cannot be saved. - Still never edit the JSON under
/usr/data/firmwareRes/config/. This module no longer reads it, but the touchscreen app still does and rewrites those files wholesale — leave it alone. - Klipper lives on the data partition. The extras install under
/usr/data/anvil/klipper/klippy/extras/, which a FlashForge OTA cannot delete — but an OTA rewrites the software component the mod boots from, so re-flash the mod after one. The#*#block inprinter.cfgsurvives either way.
Install
A package built from this repo needs no config editing at all. It ships:
- the
ff_*.pyextras, inside the klippy treeanvil-klipperinstalls - the
ff-*.cfg, symlinked into/usr/data/anvil-data/config/byanvil-link-prog.sh, so anapk upgraderepoints a link instead of rewriting a file - the
[include]lines for all seven, at the end ofprinter.base.cfg, symlinked into the same directory
/usr/data/anvil-data/config is the mod's own config directory and the only
one klippy is pointed at. It is seeded once, on the first install, with a copy
of everything in FlashForge's /usr/data/config — printer.cfg with its
#*# block, and the stock includes the mod does not ship — and that stock
directory is then left alone for good.
That is what makes the undo button work. /usr/data is the data partition, so
a stock flash does not clean it: a mod symlink left in /usr/data/config would
outlive the mod and a stock Klipper would refuse to start on an [include]
pointing into a /usr/data/anvil that is gone. Nothing of the mod's runs
during a stock flash, so not writing there is the only version of this that
works. printer.cfg is never touched by any of it either way, by design: it is
the user's file, which is also why the includes live in printer.base.cfg.
Flash, and your unit's calibration imports itself on the first boot — step 5 below says how, and step 6 how to check it.
By hand
For dropping a single edited file onto a printer that is already modded. On
the printer (ssh as pwned — this assumes a jailbroken printer; how to get
root/ssh access is covered in the community
Discord):
# 1. the klippy extras (data partition — the tree the klipper service runs)
scp pkgs/klipper/payload/klipper/klippy/extras/ff_*.py \
pwned@PRINTER:/usr/data/anvil/klipper/klippy/extras/
# 2. the config files (data partition — survives OTA). The mod's config
# directory, not FlashForge's: this is the one klippy reads.
scp pkgs/klipper-config/payload/config/ff-*.cfg \
pwned@PRINTER:/usr/data/anvil-data/config/
- Make sure something includes them. A flashed printer already does, at the
end of
printer.base.cfg. All seven are required — they are not optional drop-ins, and without them Klipper comes up as a plain printer with no toolchanger:
[include ff-toolchange.cfg]
[include ff-tool-offset.cfg]
[include ff-filament.cfg]
[include ff-print-macros.cfg]
[include ff-runout.cfg] ; after printer.base.cfg (overrides its sensor sections)
[include ff-chamber.cfg] ; M141/M191; follows whatever printer.chamber.cfg declared
[include ff-legacy.cfg] ; harmless to leave in — see step 7
If you put these in
printer.cfginstead, they must go ABOVE the#*# <---------------------- SAVE_CONFIG ---------------------->marker. Klipper treats any non-#*#line below that marker as corruption, discards the entire autosave block, and every calibrated value — PID, mesh, shaper, nozzle and dock positions — stops being read.
Only two ordering rules are real, and both are about one file overriding
another's values, which Klipper applies in include order: ff-runout.cfg
after the sensor sections in printer.base.cfg, and ff-chamber.cfg
after printer.chamber.cfg. Placement relative to [virtual_sdcard] does
not matter — ff_print takes SDCARD_PRINT_FILE/M23 over at
klippy:connect, once every section is loaded — and neither does
placement relative to the commands the G28 and SHAPER_CALIBRATE
wrappers rename, since gcode_macro defers its rename to klippy:connect
as well.
-
RESTART(or reboot). -
The factory/touchscreen calibration imports itself on the first boot after the flash — driven from outside Klipper by
bin/ff-startup.py, which thefirmwareExewrapper runs ahead of HelixScreen. It waits until klipper and moonraker are up — those two and nothing else, since that is what it talks to; the browser UI gets a short grace period and is then ignored, so a Fluidd build or one with no browser UI at all still migrates — then sends the two commands below over the moonraker API:[ff_legacy]readsextruder.json/test.json/zoffset.jsonand stages your unit's dock coordinates, nozzle and station values, station start point and any per-tool Z tune, andSAVE_CONFIGpersists them intoprinter.cfg's#*#block. That save restarts Klipper once, before the UI is up: the wizard never meets an uncalibrated machine. Then it stamps/usr/data/anvil/.firmware-config-importedand never runs again — delete the stamp to redo it. To skip the migration entirely, create the stamp before the first boot; there is no longer a switch for it. The manual form, for inspecting or after aRESTORE:FF_IMPORT_FIRMWARE_CONFIG ; APPLY=0 to only print, stage nothing SAVE_CONFIGOnly a save it can verify writes the stamp. A boot where the heater board needed several klippy restarts simply times out and tries again next boot;
/usr/data/logs/anvil-boot.logsays which service it was waiting on.Nothing to paste either way; the import only prints an
[ff_toolchange]snippet if a feed in the JSON differs from the running config (it does not on a stock unit). -
TOOLCHANGE_STATUSandTOOL_OFFSET_STATUS— every tool should show a nozzle triple and a dock position, the stationzmust be present; nothing should sayNOT CALIBRATED, "no dock position" or "unsaved calibration pending". -
Optionally remove the
[include ff-legacy.cfg]line andRESTART. Not required: the import returns early as soon as any tool has a nozzle position, so the section is inert once the import has been saved. A flashed printer keeps it included.
Calibration
The nozzle XY/Z offset calibration is the touchscreen's own sequence
(testEddyExtruderOffsetForwardTwoCheck, recovered from the binary — see
docs/notes/45-tool-offset-calibration.md
and 46-offset-calibration-recovered.md),
constants included. Take the PEI sheet off first — the calibration
station sits below the bed plane. Nothing asks you to promise that: both
commands park the carriage and measure it, probing the station Z with the
bare carriage (it must not land more than 0.8 mm above the calibrated
station_z — the check is one-sided, since a plate can only hold the probe
high) and sweeping sideways for the circle's edge. A plate left on lands
the Z probe high and has no edge, so the command refuses before any nozzle
descends (PLATE_CHECK=0 or plate_check: False skips it). Home, then:
CALIBRATE_TOOL_OFFSETS ; or, by hand:
TOOL_LOCATE_SENSOR ; empty carriage, parks the mounted tool for you
SELECT_TOOL T=0
TOOL_CALIBRATE_TOOL_OFFSET ; measures whatever is on the carriage
SAVE_CONFIG
TOOL_LOCATE_SENSOR probes the fixed under-bed station with the empty
carriage (eddy frame) and stores station_x/y/z; TOOL_CALIBRATE_TOOL_OFFSET
touches the station's cylinder in four directions with the mounted tool's
nozzle, fits a circle, repeats the pass centred on that fit and
stores the nozzle's absolute nozzle_x/y/z. Results are station-frame
absolutes per tool, so recalibrating one tool leaves the others valid;
nozzle_z − station_z is the ~3.2 mm gap the print-start Z offset uses.
Re-run TOOL_LOCATE_SENSOR whenever the station or bed is disturbed.
CALIBRATE_TOOL_OFFSETS runs both passes in one command. It is
klipper-toolchanger's documented entry point, so it is the name HelixScreen's
setup wizard and other UIs look for — the two commands above are what it calls.
calibration.md is the operator's walkthrough: the order,
the expected output, and every refusal the commands can raise.
Probe sampling. Both commands take klipper-toolchanger's parameters —
SAMPLES, SAMPLES_TOLERANCE, SAMPLES_TOLERANCE_RETRIES,
SAMPLES_RESULT (average or median), SAMPLE_RETRACT_DIST,
PROBE_SPEED — applied to every probe of the run, or set once in
[ff_tool_offset]. Left alone they follow the fork's own [e_stop <axis>]
settings, which already sample: three touches, spread rejected above
error_v (0.02 mm), retried up to main_cycle_cnt times, back_v retract
between them, averaged. So the defaults probe exactly as before this was
reachable; the parameters widen or narrow that, and add the median upstream
offers and the fork does not. Upstream's LIFT_SPEED has no counterpart:
the retract between touches runs along the probe axis, at PROBE_SPEED.
TOOL_CALIBRATE_TOOL_OFFSET SAMPLES=5 SAMPLES_RESULT=median
Note on the word "gap": station_z is where the empty carriage trips the
station, and the feature it trips sits about 12.4 mm +X of the nozzle and lower
(see notes/46-offset-calibration-recovered.md). So nozzle_z − station_z is
a nozzle-to-station-trigger distance, not a nozzle-to-eddy-coil one — the
number is right, the mental picture of an eddy measurement is not.
Per-tool first-layer tuning: Klipper's SET_GCODE_OFFSET Z_ADJUST= babystep
is one global number. Use
TOOL_Z_ADJUST TOOL=2 ADJUST=-0.02 ; live, saves nothing
TOOL_Z_ADJUST TOOL=2 ADJUST=-0.02 SAVE=1 ; and stage it
SAVE_CONFIG ; when you are happy with it
instead: it edits [ff_tool 2] z_adjust, re-applies immediately if that
tool is mounted, is added on every later grab of that tool, and persists.
Design notes
- Per-tool X/Y offsets are differences vs a base tool (T0), applied on
each grab the way
CommMgr::setGrabGcodeOffsetMgrcomputes them. Z is absolute on every grab:nozzle_z − station_z + z_adjust, the bed-frame gap the app only sets once per print (BuildPage::startPrint). This departs from the app deliberately — with the app's scheme a tool picked up outside a print sits in the raw eddy frame and a manualG1 Z0.1drives it 3 mm into the plate.TOOLCHANGE_SET_PRINT_OFFSETadds only the job terms (thermal, bed ≥ 100 °C, thin first layer) and those, plus mid-print babysteps, are carried across toolchanges as in the app. A print may start on any tool. - Calibration is stored the way Klipper's own calibrators store theirs:
absolute
nozzle_x/y/zper[ff_tool n]section (modelled on[bed_mesh <profile>]/ klipper-toolchanger's[tool Tn]) plus[ff_tool_offset] station_x/y/z, written withconfigfile.set()and persisted bySAVE_CONFIG; dock positions and the station start point are imported the same way. The offsets are derived at load.[save_variables]is deliberately not used. The stock touchscreen cannot see Klipper-side results — it keeps using its own JSON. - Everything is a Python extra (not gcode_macro) because the grab sequence
polls the grab sensor and retries up to 3 times, and the calibration
drives the fork's
e_stopprobe objects directly — a macro renders its whole template before executing and cannot poll.
Input shaper
SHAPER_CALIBRATE, TEST_RESONANCES and MEASURE_AXES_NOISE are wrapped
(ff-toolchange.cfg): they home if needed and grab a head first when the
carriage is empty, so the measured moving mass is the real one (the app's
grabVibration). Works the same from Mainsail, HelixScreen or the console;
the original parameters pass through. Which head: variable_shaper_tool
in [gcode_macro _FF_SHAPER_PREP] (default T0). The tool stays mounted
afterwards; TOOLCHANGE_PARK docks it.
Roadmap
Fool-proofing, in rough priority order:
- Run this branch on hardware. Calibration sequence, import and the safety gates are mock-tested only.
- Z-height / clearance check after picking a tool, before leaving the dock area — catch a bad grab early instead of dragging or breaking the tool on the way out.
- Block the stock touchscreen UI during Mainsail prints. The app doesn't know a print is running (it only tracks jobs it started itself), so the screen stays fully live — a stray tap can home, move the carriage, start a filament load, or fire its own toolchange into the middle of a running job. The module should lock the UI out (or at least its motion commands) while a Mainsail-started print is active.
HelixScreen / tool-changer-aware UIs
ff_toolchange also registers the Klipper objects that UIs written for
klipper-toolchanger look
for — toolchanger (name, status, tool, tool_number, tool_numbers,
tool_names, detected_tool, detected_tool_number, has_detection) and
tool T0..T3 (active, mounted, detect_state = mounted|absent from the
tool's grab sensor, extruder, heater, fan, gcode_x/y/z_offset) — and the
commands they send: SELECT_TOOL T=<n> (= T<n>), UNSELECT_TOOL [T=<n>]
(= TOOLCHANGE_PARK), INITIALIZE_TOOLCHANGER (state check, no motion),
SET_TOOL_TEMPERATURE [T=<n>] TARGET=<t> [WAIT=1],
VERIFY_TOOL_DETECTED [T=<n>] [ASYNC=…] and SELECT_TOOL_ERROR [MESSAGE=…].
status is changing while a tool selection, change, or bare park
(TOOLCHANGE_PARK / UNSELECT_TOOL) is executing. After a successful standalone
park it returns to ready; a park nested inside a toolchange leaves it
changing until the outer operation finishes. Raw sensor validation remains
active throughout: ff_toolchange.state_ok and state_reason still report
invalid combinations, including the transient dock/grab overlap during parking.
Outside an active operation, invalid sensor state reports error, else ready.
We keep no commanded tool state, so detected_tool* always equals tool*:
both are derived from the dock and grab sensors.
SELECT_TOOL, UNSELECT_TOOL and TOOLCHANGE_PARK accept upstream's
RESTORE_AXIS=<xyz>: the G-code position is captured before the change and
replayed after it, X/Y first and Z last so the nozzle is never dragged across
the part. A G-code position is replayed, not a machine one, so it is read back
through the offsets in force after the change — the new tool's nozzle lands
where the old one was. The default is restore_axis in [ff_toolchange],
itself empty: nothing is restored unless asked, which is how this machine has
always behaved. Restoring Z after an UNSELECT_TOOL is the sharp edge, since
parking zeroes the tool offsets and the same G-code Z becomes a different
machine Z (~3.2 mm, this tool's nozzle-to-station-trigger gap -- the station,
not the eddy coil; see the note under Calibration).
When X or Y is restored after a real change, the trip back can be made gentler
on the part. Three groups of options in [ff_toolchange], all zero as shipped:
restore_z_hopraises the old tool that far before it crosses the part to its dock, and the new tool travels back at that height and descends at the target.restore_retractpulls that much filament back while the new tool is still seated in its dock, before it is drawn out, so a hot nozzle does not drag an ooze string. A tool below the minimum extrusion temperature is not retracted.restore_unretractpushes back at most that much at the target. Setting it below the retract is deliberate: the slicer's own extrusion supplies the rest while moving, instead of a blob from a stationary prime.
Feeds are restore_z_feed, restore_retract_feed and
restore_unretract_feed. Re-selecting the tool that is already mounted, and any
change that does not restore X or Y, behaves as before.
SET_TOOL_TEMPERATURE addresses the extruder behind the tool; WAIT=1 waits
only for heat-up, as Klipper's own TEMPERATURE_WAIT MINIMUM does.
VERIFY_TOOL_DETECTED accepts ASYNC and ignores it — we read switches after
a wait_moves, which costs nothing to do inline. SELECT_TOOL_ERROR aborts
the running script; we hold no error latch to set, because status is derived
from the sensors every time it is asked for.
Upstream's docking-mode and tool-parameter commands (TEST_TOOL_DOCKING,
ENTER_DOCKING_MODE, SET_TOOL_PARAMETER and friends) are deliberately
absent: calibration here is TOOL_CALIBRATE_TOOL_OFFSET /
TOOL_LOCATE_SENSOR / TOOL_Z_ADJUST, already tied to the factory numbers.
ASSIGN_TOOL is refused — remap tools in the slicer. Nothing to enable; it is
always on. part_fan in [ff_toolchange] is what gets reported as each
tool's fan (shared fan_generic fanM106 on this machine). ff_toolchange
itself stays (the printer-database fingerprint keys on it); the new objects
sit alongside.
Verify from any machine that can reach Moonraker (port 7125):
curl -s http://PRINTER:7125/printer/objects/list | grep -o '"toolchanger"\|"tool T[0-3]"'
# expect all five names
curl -s 'http://PRINTER:7125/printer/objects/query?toolchanger&tool%20T0'
# toolchanger.status "ready", tool_number -1 (parked) or 0..3;
# tool T0: mounted/active false, detect_state "absent" while docked
Then SELECT_TOOL T=0 from the console and poll the query again: status
goes changing, then ready with tool_number: 0 and tool T0
detect_state: "mounted". HelixScreen's log on connect should read
[Moonraker Client] Subscribing to toolchanger + 4 tool objects, and its
tool panel shows the mounted head and Park/Select per tool. The resonance
commands are wrapped so they grab a head first (see Input shaper).
HelixScreen then runs its Tool
Changer backend: tool slots in the sidebar and print status, per-tool
temperatures and offsets, Spoolman per tool, the plain single-extruder runout
dialog. Drop pkgs/helixscreen/payload/helixscreen/config/printer_database.d/flashforge_creator5.json into HelixScreen's
config/printer_database.d/ for auto-detection (ams_type: tool_changer,
z_offset_calibration_strategy: firmware_managed). Its default Load/Unload buttons only mount/unmount the tool (SELECT_TOOL /
UNSELECT_TOOL); to actually feed or pull filament assign LOAD_FILAMENT,
UNLOAD_FILAMENT and PURGE from pkgs/klipper-config/payload/config/ff-filament.cfg
in Settings → Macro Buttons — a user-assigned macro outranks the backend, and
the parameter dialog picks up TOOL / TEMP / PURGE_TEMP from the macros.
Reverse-engineering notes
Condensed notes from the firmwareExe analysis — recovered sequences, binary
addresses, JSON semantics — live in docs/notes/:
architecture overview, the Klipper-fork delta (including the Tn interception),
who decides what — app vs Klipper
(heaters, runout, doors, calibration; which "features" are dead code),
the verified grab/release sequences, the offset model, the recovered
nozzle-offset calibration and its Klipper port, and the full print
lifecycle with the deliberate divergences listed.
Support