Pure renames, no content changes, so `git log --follow` walks straight back into the toolchange history imported by the previous commit. klippy-extras/ff_*.py -> payload/klipper/extras/ config/ff-*.cfg -> payload/klipper/config/ helixscreen/*.json -> payload/helixscreen/printer_database.d/ orca/ -> assets/orca/ docs/notes/ -> docs/notes/ README.md -> docs/toolchange.md payload/ is the right home for the first three: they are files that ship to the printer, which is what everything else under payload/ is. The Orca snippets go to assets/ instead -- they are pasted into a slicer on the desktop and never reach the machine. bin/patch.sh still reads them from $TOOLCHANGE; the next commit points it here. Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01GgNhSa1Qvwvxb2nQXT6b1Y
60 lines
2.7 KiB
Markdown
60 lines
2.7 KiB
Markdown
# Error code table (English strings, complete)
|
||
|
||
Useful as a behavioral spec — every hardware fault the stock system distinguishes.
|
||
|
||
## Toolchanger
|
||
- E0127–E0130: T1–T4 not in dock. Cannot pick up extruder.
|
||
- E0051–E0054: T1–T4 pickup failed.
|
||
- E0131–E0134: T1–T4 already in dock. Cannot release extruder.
|
||
- E0135–E0138: T1–T4 release failed.
|
||
- E0139: Extruder mount sensor not triggered
|
||
- E0140: Extruder dock sensor not triggered
|
||
- E0141: Extruder mount sensor still triggered
|
||
- E0142: Extruder dock sensor still triggered
|
||
- E0143: State error after extruder pickup
|
||
- E0144: State error after extruder release
|
||
- E0145: Lock motor current abnormal
|
||
- E0146: Unlock sensor not triggered.
|
||
- E0160: Cannot release extruder. Homing failed.
|
||
- E0165: extruder not installed, can not print.
|
||
|
||
## Leveling / probe (eddy)
|
||
- E0041: Leveling sensor cannot reset.
|
||
- E0147: Build plate not removed. Please check.
|
||
- E0148: The leveling extreme values are out of range. Please clean the platform or adjust its flatness, then try again.
|
||
- E0149: Sensor not triggered at max travel.
|
||
- E0150: Homing timeout.
|
||
- E0151: Eddy current probe triggered before move.
|
||
- E0152: During leveling, the values measured multiple times are out of range. Please clean the platform and nozzle, then try again.
|
||
- E0153: During nozzle offset calibration, the values measured multiple times are out of range. Please clean the eddy-current sensor and nozzle, then try again.
|
||
- E0161: Bed eddy current position abnormal. Please check.
|
||
- E0167/E0168: The platform is not installed. Please install it and try again.
|
||
|
||
## Heating
|
||
- E0063–E0066: Extruder 1–4 heating error.
|
||
- E0123: Bed heating error.
|
||
- E0077: Chamber heating error.
|
||
- E0154: Drive motor temp abnormal. Please check if PCB fan is on.
|
||
|
||
## Axes / homing
|
||
- E0012/E0013/E0014: X/Y/Z-axis signal not triggered.
|
||
- E0155/E0156/E0157: X/Y/Z-axis limit still triggered after retract.
|
||
- E0158: Sensor error. E0159: Homing error.
|
||
|
||
## Communication
|
||
- E0002: MCU communication lost.
|
||
- E0124: Extruder mount MCU communication lost. (eboard)
|
||
- E0125: Heater board MCU communication lost. (eheaterboard)
|
||
- E0126: Leveling board MCU communication lost. (levelboard)
|
||
- E0170–E0173: Lost communication with main/extruder/heater/level mcu
|
||
- E0005: Printer is not ready. Please check if the wiring is correct.
|
||
|
||
## Print-time
|
||
- E0162: Paused. Filament runout.
|
||
- E0163: Paused. Clog detected.
|
||
- E0164: Paused. Spaghetti detected. (camera AI)
|
||
- E0166: Print file error. E0169: Printer model mismatch. Please re-slice.
|
||
- E0175: Internal error on command. E0176: The gcode move out of range.
|
||
- E0021: Cannot open camera. / Camera not recognized.
|
||
- E0174: Copy log error. E0999: Unknown error.
|