Fourteen sections, install through troubleshooting, in the one file that existed when there was nowhere else to put them. The site gave the manual a home; this moves it there and orders it by what the reader is doing rather than by which subsystem owns the answer. Someone whose printer will not boot should not have to know that the symptom table lives in a file called hardware-testing.md. Three topics were documented two and three times over, and each copy was free to drift: install in README and toolchange.md, calibration in README, calibration.md and toolchange.md, slicer setup in README and toolchange.md, "before you start" in all three. Each is now in one place. The owner path is Is this for you -> Installing -> After the flash -> Your first print -> Nozzle-offset calibration -> Printing -> Upgrading -> When something goes wrong, with error codes, versions and how-it-works behind a Reference group. The README keeps what a front door keeps: what this is, the status checkboxes, what you give up, which file to download, and where to go next. toolchange.md was four documents in one 38 KB file. The owner half -- slicer setup, filament, runout, the offset check before a first print -- is in Printing and Your first print; the design notes, input shaper, roadmap, HelixScreen and reverse-engineering notes stay, and the page moves to Internals. hardware-testing.md was split down the middle by audience the same way: the go/no-go checks and the symptom table were the owner's, and only keeping the two verification files honest as the macros change is ours. Two things this fixes rather than moves. The error-code table was notes/70-error-codes.md, an internals note the README sent owners to; it is docs/error-codes.md now, a page. And toolchange.md still opened "Not yet run on hardware" while the README's checkboxes described a Creator 5 Pro that has been printing for weeks -- the two pages have disagreed since the first hardware run. Contributors are deferred, as agreed: those pages are regrouped, not rewritten. The nav says so. Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01S3XZh4SqPdXAowVndz6tMr
2.7 KiB
2.7 KiB
Error code table (English strings, complete)
Useful as a behavioral spec — every hardware fault the stock system distinguishes.
Toolchanger
- E0127–E0130: T1–T4 not in dock. Cannot pick up extruder.
- E0051–E0054: T1–T4 pickup failed.
- E0131–E0134: T1–T4 already in dock. Cannot release extruder.
- E0135–E0138: T1–T4 release failed.
- E0139: Extruder mount sensor not triggered
- E0140: Extruder dock sensor not triggered
- E0141: Extruder mount sensor still triggered
- E0142: Extruder dock sensor still triggered
- E0143: State error after extruder pickup
- E0144: State error after extruder release
- E0145: Lock motor current abnormal
- E0146: Unlock sensor not triggered.
- E0160: Cannot release extruder. Homing failed.
- E0165: extruder not installed, can not print.
Leveling / probe (eddy)
- E0041: Leveling sensor cannot reset.
- E0147: Build plate not removed. Please check.
- E0148: The leveling extreme values are out of range. Please clean the platform or adjust its flatness, then try again.
- E0149: Sensor not triggered at max travel.
- E0150: Homing timeout.
- E0151: Eddy current probe triggered before move.
- E0152: During leveling, the values measured multiple times are out of range. Please clean the platform and nozzle, then try again.
- E0153: During nozzle offset calibration, the values measured multiple times are out of range. Please clean the eddy-current sensor and nozzle, then try again.
- E0161: Bed eddy current position abnormal. Please check.
- E0167/E0168: The platform is not installed. Please install it and try again.
Heating
- E0063–E0066: Extruder 1–4 heating error.
- E0123: Bed heating error.
- E0077: Chamber heating error.
- E0154: Drive motor temp abnormal. Please check if PCB fan is on.
Axes / homing
- E0012/E0013/E0014: X/Y/Z-axis signal not triggered.
- E0155/E0156/E0157: X/Y/Z-axis limit still triggered after retract.
- E0158: Sensor error. E0159: Homing error.
Communication
- E0002: MCU communication lost.
- E0124: Extruder mount MCU communication lost. (eboard)
- E0125: Heater board MCU communication lost. (eheaterboard)
- E0126: Leveling board MCU communication lost. (levelboard)
- E0170–E0173: Lost communication with main/extruder/heater/level mcu
- E0005: Printer is not ready. Please check if the wiring is correct.
Print-time
- E0162: Paused. Filament runout.
- E0163: Paused. Clog detected.
- E0164: Paused. Spaghetti detected. (camera AI)
- E0166: Print file error. E0169: Printer model mismatch. Please re-slice.
- E0175: Internal error on command. E0176: The gcode move out of range.
- E0021: Cannot open camera. / Camera not recognized.
- E0174: Copy log error. E0999: Unknown error.