load_cell_probe: Improve precision for slow ADCs (#7301)
By applying a non-linear fit of a piecewise function with a linear region for the Z positions below the point of contact and a constant "tare" region, the optimal Z position can be determined with greater precision, even beyond the ADC sample intervals. This is particularly helpful when using a relatively slow ADC like the HX711. Signed-off-by: Martin Hierholzer <martin@hierholzer.info>
This commit is contained in:
1 parent
0499b30374
commit
fe4eb8650b
2 files changed
+215
-6
No files matched your search
@@ -212,6 +212,34 @@ the frame in multiple places. Anodized aluminum extrusions do not conduct
|
||||
electricity well. You might need to sand the area where the grounding wire
|
||||
is attached to make good electrical contact.
|
||||
|
||||
#### Interpolation
|
||||
To increase the precision of the probing result, the position of the first
|
||||
contact between nozzle and bed can be estimated by fitting a piecewise function
|
||||
to the measured data. The data will consist of two regions: while the nozzle is
|
||||
above the bed, the force will be constant (at the tare value). When the nozzle
|
||||
is in contact with the bed, the force will increase linearly with decreasing z
|
||||
position. A piecewise function is fitted to the data and the optimal z position
|
||||
of the split point is found by minimising the error squared. This enables a
|
||||
resolution finer than the distance between the sampling points and will also be
|
||||
less sensitive to noise.
|
||||
|
||||
Due to both physical and technical reasons, the interpolation uses data
|
||||
collected during an additional ascending movement after the initial descending
|
||||
move. The first 300ms of data collected during the ascending move will
|
||||
be used for the fit (this minimises the influence of tare drifts). The
|
||||
collected data must contain enough samples for the fit: at least 3 samples each
|
||||
below and above the contact point are required.
|
||||
|
||||
It is recommended to use a relatively high trigger force for the probe to have
|
||||
a strong enough signal. If you have too few samples below the contact point,
|
||||
try increasing the `trigger_force` or reducing the `lift_speed`. However, if
|
||||
the `lift_speed` is too small, there will be too few samples above the contact
|
||||
point due to the 300ms window.
|
||||
|
||||
The distance of the ascending move can be configured through the
|
||||
`sample_retract_dist` parameter.
|
||||
|
||||
|
||||
## Load Cell Probe Setup
|
||||
|
||||
This section covers the process for commissioning a load cell probe.
|
||||
|
||||
@@ -3,8 +3,11 @@
|
||||
# Copyright (C) 2025 Gareth Farrington <gareth@waves.ky>
|
||||
#
|
||||
# This file may be distributed under the terms of the GNU GPLv3 license.
|
||||
import logging, math
|
||||
import mcu
|
||||
import json
|
||||
import logging
|
||||
import math, sys
|
||||
import mathutil
|
||||
|
||||
from . import hx71x
|
||||
from . import ads1220
|
||||
from . import ads131m0x
|
||||
@@ -15,6 +18,12 @@ np = None # delay NumPy import until configuration time
|
||||
# MCU SOS filter scaled to "fractional grams" for consistent sensor precision
|
||||
FRAC_GRAMS_CONV = 32768.0
|
||||
|
||||
# Minimum ascent samples needed for piecewise least-squares fit
|
||||
FIT_MIN_POINTS = 3
|
||||
|
||||
# Time window for collecting ascent data in seconds
|
||||
ASCENT_DATA_WINDOW_SECONDS = 0.3
|
||||
|
||||
|
||||
class TapAnalysis:
|
||||
def __init__(self, samples):
|
||||
@@ -236,6 +245,16 @@ def check_sensor_errors(results, printer):
|
||||
return samples
|
||||
|
||||
|
||||
# compute Z position at a given print_time using stepper history
|
||||
def _lookup_z_pos(toolhead, pos_time):
|
||||
kin = toolhead.get_kinematics()
|
||||
steppers = kin.get_steppers()
|
||||
kin_spos = {s.get_name(): s.mcu_to_commanded_position(
|
||||
s.get_past_mcu_position(pos_time))
|
||||
for s in steppers}
|
||||
return kin.calc_position(kin_spos)[2]
|
||||
|
||||
|
||||
class LoadCellProbeConfigHelper:
|
||||
def __init__(self, config, load_cell_inst):
|
||||
self._printer = config.get_printer()
|
||||
@@ -248,7 +267,7 @@ class LoadCellProbeConfigHelper:
|
||||
self._trigger_force_param = floatParamHelper(config, 'trigger_force',
|
||||
default=75, minval=10, maxval=250)
|
||||
self._force_safety_limit_param = floatParamHelper(config,
|
||||
'force_safety_limit', minval=100, maxval=5000, default=2000)
|
||||
'force_safety_limit', minval=100, maxval=10000, default=2000)
|
||||
|
||||
def get_tare_samples(self, gcmd=None):
|
||||
tare_time = self._tare_time_param.get(gcmd)
|
||||
@@ -387,21 +406,44 @@ class TappingMove:
|
||||
header = {"header": ["probe_tap_event"]}
|
||||
self._clients.add_mux_endpoint("load_cell_probe/dump_taps",
|
||||
"load_cell_probe", name, header)
|
||||
self._best_fit = LCBestFit(self._printer)
|
||||
|
||||
# perform a probing move and a pullback move
|
||||
def run_tap(self, gcmd):
|
||||
# do the descending move
|
||||
epos, collector = self._load_cell_probing_move.probing_move(gcmd)
|
||||
# collect samples from the tap
|
||||
toolhead = self._printer.lookup_object('toolhead')
|
||||
toolhead.flush_step_generation()
|
||||
|
||||
# Lift the toolhead while collecting the samples we will use for
|
||||
# the fit. The ascent data shall cover both the contact region
|
||||
# (force still applied) and free-air region (no force = tare).
|
||||
ascent_start_time = toolhead.get_last_move_time()
|
||||
|
||||
# load_cell_retract_dist is mapped to sample_retract_dist in
|
||||
# LoadCellParameterHelper
|
||||
params = \
|
||||
self._load_cell_probing_move._param_helper.get_probe_params(gcmd)
|
||||
lift_dist = params['load_cell_retract_dist']
|
||||
lift_pos = toolhead.get_position()
|
||||
lift_pos[2] += lift_dist
|
||||
toolhead.manual_move(lift_pos, params['lift_speed'])
|
||||
|
||||
# Collect samples until the end of the ascent
|
||||
move_end = toolhead.get_last_move_time()
|
||||
results = collector.collect_until(move_end)
|
||||
samples = check_sensor_errors(results, self._printer)
|
||||
|
||||
# Perform fit on the ascent data
|
||||
corrected_z = self._analyze_ascent(gcmd, samples, ascent_start_time,
|
||||
toolhead, epos[2])
|
||||
# Replace the probe result with the fitted Z position
|
||||
epos[2] = corrected_z
|
||||
|
||||
# Analyze the tap data
|
||||
ppa = TapAnalysis(samples)
|
||||
# broadcast tap event data:
|
||||
self._clients.send({'tap': ppa.to_dict()})
|
||||
|
||||
self._is_last_result_valid = True
|
||||
self._last_result = epos[2]
|
||||
return epos, self._is_last_result_valid
|
||||
@@ -412,6 +454,134 @@ class TappingMove:
|
||||
'is_last_tap_valid': self._is_last_result_valid
|
||||
}
|
||||
|
||||
def _analyze_ascent(self, gcmd, all_samples, ascent_start_time, toolhead,
|
||||
raw_z):
|
||||
# Collect samples actually belonging to the ascent. We use a limited
|
||||
# time window to minimise the influence of baseline wandering.
|
||||
data = []
|
||||
for s in all_samples:
|
||||
if s[0] >= ascent_start_time and \
|
||||
s[0] <= ascent_start_time + ASCENT_DATA_WINDOW_SECONDS:
|
||||
data.append((s[1], _lookup_z_pos(toolhead, s[0])))
|
||||
|
||||
if self._load_cell_probing_move._mcu.is_fileoutput():
|
||||
# In debugging mode: inject dummy data
|
||||
data = [(0.0, 0.0), (10.0, 0.1), (20.0, 0.2), (25.0, 0.3),
|
||||
(25.0, 0.4), (25.0, 0.5)]
|
||||
|
||||
# Log ascent data in JSON format for easy debugging
|
||||
#logging.info("Load cell probe ascent data: %s", json.dumps(data))
|
||||
|
||||
# Check that we have enough samples early to avoid exceptions
|
||||
if len(data) < 2*FIT_MIN_POINTS:
|
||||
raise self._printer.command_error(
|
||||
"Insufficient ascent samples (%d total, need >= %d "
|
||||
"each) for piecewise fit" % (len(data), 2*FIT_MIN_POINTS))
|
||||
|
||||
# Perform the actual fit
|
||||
z_contact, below_count, above_count, depress_slope = \
|
||||
self._best_fit.find_best_fit(data)
|
||||
|
||||
# We require at least 3 samples on each side of the split point to
|
||||
# ensure a good fit and precise tare compensation.
|
||||
if below_count < FIT_MIN_POINTS or above_count < FIT_MIN_POINTS:
|
||||
raise self._printer.command_error(
|
||||
"Insufficient ascent samples (%d below, %d above, need >= %d "
|
||||
"each) for piecewise fit" % (below_count, above_count,
|
||||
FIT_MIN_POINTS))
|
||||
|
||||
gcmd.respond_info("Load cell probe fit: n_below=%d n_above=%d"
|
||||
" z_contact=%.4f raw=%.4f delta=%.4f"
|
||||
" depress_slope=%.4f" % (
|
||||
below_count, above_count, z_contact, raw_z,
|
||||
raw_z - z_contact, depress_slope))
|
||||
|
||||
if self._load_cell_probing_move._mcu.is_fileoutput():
|
||||
# In debugging mode: check fit result
|
||||
if abs(z_contact - 0.25) > 0.01:
|
||||
raise self._printer.command_error(
|
||||
"Load cell probe fit result incorrect")
|
||||
|
||||
return z_contact
|
||||
|
||||
|
||||
# Given a list of (grams, z) pairs, find the coefficients z_contact,
|
||||
# grams_contact, depress_slope, slope that best fit the data to the
|
||||
# formulas `grams = grams_contact + depress_slope*(z-z_contact)` when
|
||||
# z<=z_contact and `grams = grams_contact` when z>=z_contact. This
|
||||
# implements a form of non-linear least squares.
|
||||
class LCBestFit:
|
||||
def __init__(self, printer):
|
||||
self._printer = printer
|
||||
|
||||
def _calc_least_squares(self, samples, est_z_contact):
|
||||
len_samples = len(samples)
|
||||
eqs = [[0.] * 2 for i in range(len_samples)]
|
||||
ans = [[0.] for i in range(len_samples)]
|
||||
for i, (step_z, sensor_grams) in enumerate(samples):
|
||||
a = ans[i]
|
||||
eq = eqs[i]
|
||||
if step_z <= est_z_contact:
|
||||
# 1*c0 + (z-ezc)*c1 = grams
|
||||
eq[0] = 1.
|
||||
eq[1] = step_z - est_z_contact
|
||||
else:
|
||||
# 1*c0 = grams
|
||||
eq[0] = 1.
|
||||
eq[1] = 0.
|
||||
a[0] = sensor_grams
|
||||
eqst = mathutil.mat_transp(eqs)
|
||||
eqst_eqs = mathutil.mat_mat_mul(eqst, eqs)
|
||||
eqst_ans = mathutil.mat_mat_mul(eqst, ans)
|
||||
coeffs = mathutil.gaussian_solve(eqst_eqs, eqst_ans)
|
||||
if coeffs is None:
|
||||
return sys.float_info.max, [[0.]] * 2
|
||||
rel_err = -sum([c[0]*a[0] for c, a in zip(coeffs, eqst_ans)])
|
||||
return rel_err, coeffs
|
||||
|
||||
def find_best_fit(self, data):
|
||||
# Change base of grams/z measurements to improve numerical stability
|
||||
base_z = .5 * (data[0][1] + data[-1][1])
|
||||
base_grams = .5 * (data[0][0] + data[-1][0])
|
||||
samples = [(d[1] - base_z, d[0] - base_grams) for d in data]
|
||||
|
||||
def _run_fit(sample_set):
|
||||
"""Run the binary search fit on the given sample set."""
|
||||
min_z = best_z = sample_set[0][0]
|
||||
max_z = sample_set[-1][0]
|
||||
best_err = sys.float_info.max
|
||||
best_coeffs = [[0.]]*2
|
||||
while max_z - min_z > 0.000050:
|
||||
mid_z = (min_z + max_z) * .5
|
||||
if best_z < mid_z:
|
||||
guess_z = (best_z + max_z) * .5
|
||||
else:
|
||||
guess_z = (min_z + best_z) * .5
|
||||
guess_err, guess_coeffs = \
|
||||
self._calc_least_squares(sample_set, guess_z)
|
||||
if guess_err < best_err:
|
||||
if guess_z > best_z:
|
||||
min_z = best_z
|
||||
else:
|
||||
max_z = best_z
|
||||
best_z = guess_z
|
||||
best_err = guess_err
|
||||
best_coeffs = guess_coeffs
|
||||
else:
|
||||
if guess_z > best_z:
|
||||
max_z = guess_z
|
||||
else:
|
||||
min_z = guess_z
|
||||
return best_z, best_coeffs
|
||||
|
||||
est_z, coeffs = _run_fit(samples)
|
||||
|
||||
# Count number of samples below the estimated z_contact
|
||||
n_below = len(sorted([s for s in samples if s[0] <= est_z],
|
||||
key=lambda s: abs(s[0] - est_z)))
|
||||
depress_slope = coeffs[1][0]
|
||||
|
||||
return base_z + est_z, n_below, len(samples) - n_below, depress_slope
|
||||
|
||||
# ProbeSession that implements Tap logic
|
||||
class TapSession:
|
||||
@@ -473,6 +643,17 @@ class LoadCellProbeCommands:
|
||||
gcmd.respond_info("Test complete, %s taps detected" % (taps,))
|
||||
|
||||
|
||||
class LoadCellParameterHelper:
|
||||
def __init__(self, config):
|
||||
self._param_helper = probe.ProbeParameterHelper(config)
|
||||
def get_probe_params(self, gcmd=None):
|
||||
params = self._param_helper.get_probe_params(gcmd)
|
||||
# Disable lift in calling code as it is done within tap process
|
||||
params['load_cell_retract_dist'] = params['sample_retract_dist']
|
||||
params['sample_retract_dist'] = 0.
|
||||
return params
|
||||
|
||||
|
||||
class LoadCellPrinterProbe:
|
||||
def __init__(self, config):
|
||||
cfg_error = config.error
|
||||
@@ -500,7 +681,7 @@ class LoadCellPrinterProbe:
|
||||
continuous_tare_filter_helper = ContinuousTareFilterHelper(
|
||||
config, sensor, sos_filter)
|
||||
# Probe Interface
|
||||
self._param_helper = probe.ProbeParameterHelper(config)
|
||||
self._param_helper = LoadCellParameterHelper(config)
|
||||
self._cmd_helper = probe.ProbeCommandHelper(config, self)
|
||||
self._probe_offsets = probe.ProbeOffsetsHelper(config)
|
||||
load_cell_probing_move = LoadCellProbingMove(config, self._load_cell,
|
||||
|
||||
Reference in new issue
Block a user